Operating voltage to 1000 V. Axial and diamter contraction, monolithic piezoceramic actuator with minimal geometric tolerances
Industry and research. For microdosing, micromanipulation
Dimensions L × OD × ID | Max. operating voltage | Electrical capacitance | Max. axial contraction | Max. diameter contraction | |
|---|---|---|---|---|---|
V | nF | µm | µm | ||
PT120.00 | 20 mm × 2.2 mm × 1 mm | 500 | 3 | 5 | 0.7 |
PT130.90 | 30 mm × 3.2 mm × 2.2 mm | 500 | 12 | 9 | 0.9 |
PT130.10 | 30 mm × 6.35 mm × 5.35 mm | 500 | 18 | 9 | 1.8 |
PT130.20 | 30 mm × 10 mm × 9 mm | 500 | 36 | 9 | 3 |
PT130.50 | 30 mm × 20 mm × 18 mm | 1000 | 35 | 9 | 6 |
PT140.70 | 40 mm × 40 mm × 38 mm | 1000 | 70 | 15 | 12 |
Electrical capacitance: Tolerance ±20 %, measured at 1 Vpp, 1 kHz, RT.
Maximum contraction at maximum operating voltage.
Piezo ceramic type: PIC151.
Inner electrode on positive potential. Fired silver-plated electrodes inside and outside as standard. Option: Outer electrode thin film (CuNi, Au).
Ask about custom designs!