Products PI - Nanopositioning Piezo Flexure Stages Multi-Axis Piezo Flexure Stages
P-561 • P-562 • P-563 PIMars Nanopositioning Stage
High-Precision Nanopositioner for up to 3 Axes
  • Parallel kinematics in the X and Y axes for faster response times and greater multi-axis accuracy
  • Travel ranges to 300 × 300 × 300 µm
  • Highest linearity due to capacitive sensors
  • Zero-play and highly accurate flexure guides
  • Excellent scanning flatness
  • High dynamics XYZ version
  • Clear aperture 66 mm × 66 mm
  • Outstanding lifetime thanks to PICMA® piezo actuators
  • UHV versions to 10-9 hPa

Application fields

  • Scanning microscopy
  • Mask / wafer positioning
  • Interferometry
  • Measuring technology
  • Biotechnology
  • Scanning and screening

Outstanding lifetime due to PICMA® piezo actuators

The patented PICMA® piezo actuators are all-ceramic insulated. This protects them against humidity and failure resulting from an increase in leakage current. PICMA® actuators offer an up to ten times longer lifetime than conventional polymer-insulated actuators. 100 billion cycles without a single failure are proven.

Subnanometer resolution with capacitive sensors

Capacitive sensors measure with subnanometer resolution without contacting. They guarantee excellent linearity of motion, long-term stability, and a bandwidth in the kHz range.

High guiding accuracy due to zero-play flexure guides

Flexure guides are free of maintenance, friction, and wear, and do not require lubrication. Their stiffness allows high load capacity and they are insensitive to shock and vibration. They work in a wide temperature range.

Automatic configuration and fast component exchange

Mechanics and controllers can be can be combined as required and exchanged quickly. All servo and linearization parameters are stored in the ID chip of the mechanics' D-sub connector. The auto calibration function on the digital controller automatically uses this data every time the controller is switched on.

High tracking accuracy in the nanometer range due to parallel position measuring

All degrees of freedom are measured against a single fixed reference. Undesired crosstalk between axes can be actively compensated (active guiding) in real time (depending on the bandwidth). High tracking accuracy is achieved in the nanometer range even in dynamic operation.

Suitable for sophisticated vacuum applications

All components used in the piezo systems are excellently suited for use in vacuum. No lubricant or grease is necessary for operating. Polymer-free piezo systems allow particularly low outgas rates.

Motion P-561.3CD P-561.3CL P-562.3CD P-562.3CL P-563.3CD P-563.3CL P-561.3DD Tolerance
Active axes X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z  
Travel range in X 100 µm 100 µm 200 µm 200 µm 300 µm 300 µm 45 µm  
Travel range in Y 100 µm 100 µm 200 µm 200 µm 300 µm 300 µm 45 µm  
Travel range in Z 100 µm 100 µm 200 µm 200 µm 300 µm 300 µm 15 µm  
Travel range in X, open loop, at -20 to 120 V 150 µm 150 µm 300 µm 300 µm 340 µm 340 µm 58 µm +20 / -0 %
Travel range in Y, open loop, at -20 to +120 V 150 µm 150 µm 300 µm 300 µm 340 µm 340 µm 58 µm +20 / -0 %
Travel range in Z, open loop, at -20 to 120 V 150 µm 150 µm 300 µm 300 µm 340 µm 340 µm 18 µm +20 / -0 %
Linearity error in X 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % max.
Linearity error in Y 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % max.
Linearity error in Z 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.03 % 0.08 % max.
Flatness (Linear crosstalk in X with motion in Z) ± 30 nm ± 30 nm ± 50 nm ± 50 nm ± 50 nm ± 50 nm ± 20 nm typ.
Straightness (Linear crosstalk in Y with motion in Z) ± 30 nm ± 30 nm ± 50 nm ± 50 nm ± 50 nm ± 50 nm ± 20 nm typ.
Flatness (Linear crosstalk in Z with motion in X) ± 15 nm ± 15 nm ± 20 nm ± 20 nm ± 25 nm ± 25 nm ± 10 nm typ.
Flatness (Linear crosstalk in Z with motion in Y) ± 15 nm ± 15 nm ± 20 nm ± 20 nm ± 25 nm ± 25 nm ± 10 nm typ.
Pitch (Rotational crosstalk in θX with motion in Y) ± 1 µrad ± 1 µrad ± 2 µrad ± 2 µrad ± 2 µrad ± 2 µrad ± 3 µrad typ.
Yaw (Rotational crosstalk in θX with motion in Z) ± 15 µrad ± 15 µrad ± 20 µrad ± 20 µrad ± 25 µrad ± 25 µrad ± 3 µrad typ.
Pitch (Rotational crosstalk in θY with motion in X) ± 1 µrad ± 1 µrad ± 2 µrad ± 2 µrad ± 2 µrad ± 2 µrad ± 3 µrad typ.
Pitch (Rotational crosstalk in θY with motion in Z) ± 15 µrad ± 15 µrad ± 20 µrad ± 20 µrad ± 25 µrad ± 25 µrad ± 3 µrad typ.
Yaw (Rotational crosstalk in θZ with motion in X) ± 6 µrad ± 6 µrad ± 10 µrad ± 10 µrad ± 10 µrad ± 10 µrad ± 3 µrad typ.
Yaw (Rotational crosstalk in θZ with motion in Y) ± 6 µrad ± 6 µrad ± 10 µrad ± 10 µrad ± 10 µrad ± 10 µrad ± 3 µrad typ.
Positioning P-561.3CD P-561.3CL P-562.3CD P-562.3CL P-563.3CD P-563.3CL P-561.3DD Tolerance
Repeatability in X 2 nm 2 nm 2 nm 2 nm 2 nm 2 nm 2 nm typ.
Repeatability in Y 2 nm 2 nm 2 nm 2 nm 2 nm 2 nm 2 nm typ.
Repeatability in Z 2 nm 2 nm 4 nm 4 nm 4 nm 4 nm 2 nm typ.
Resolution in X, open loop 0.2 nm 0.2 nm 0.4 nm 0.4 nm 0.5 nm 0.5 nm 0.1 nm typ.
Resolution in Y, open loop 0.2 nm 0.2 nm 0.4 nm 0.4 nm 0.5 nm 0.5 nm 0.1 nm typ.
Resolution in Z, open loop 0.2 nm 0.2 nm 0.4 nm 0.4 nm 0.5 nm 0.5 nm 0.1 nm typ.
Integrated sensor Capacitive, indirect position measuring Capacitive, indirect position measuring Capacitive, indirect position measuring Capacitive, indirect position measuring Capacitive, indirect position measuring Capacitive, indirect position measuring Capacitive, indirect position measuring  
System resolution in X 0.8 nm 0.8 nm 1 nm 1 nm 2 nm 2 nm 0.2 nm  
System resolution in Y 0.8 nm 0.8 nm 1 nm 1 nm 2 nm 2 nm 0.2 nm  
System resolution in Z 0.8 nm 0.8 nm 1 nm 1 nm 2 nm 2 nm 0.2 nm  
Drive Properties P-561.3CD P-561.3CL P-562.3CD P-562.3CL P-563.3CD P-563.3CL P-561.3DD Tolerance
Drive type PICMA® PICMA® PICMA® PICMA® PICMA® PICMA® PICMA®  
Electrical capacitance in X 5.2 µF 5.2 µF 7.4 µF 7.4 µF 7.4 µF 7.4 µF 38 µF ±20 %
Electrical capacitance in Y 5.2 µF 5.2 µF 7.4 µF 7.4 µF 7.4 µF 7.4 µF 38 µF ±20 %
Electrical capacitance in Z 10.4 µF 10.4 µF 14.8 µF 14.8 µF 14.8 µF 14.8 µF 6 µF ±20 %
Mechanical Properties P-561.3CD P-561.3CL P-562.3CD P-562.3CL P-563.3CD P-563.3CL P-561.3DD Tolerance
Guide Flexure guide with lever amplification Flexure guide with lever amplification Flexure guide with lever amplification Flexure guide with lever amplification Flexure guide with lever amplification Flexure guide with lever amplification Flexure guide with direct drive  
Resonant frequency in X, unloaded 190 Hz 190 Hz 160 Hz 160 Hz 140 Hz 140 Hz 920 Hz ±20 %
Resonant frequency in X, under load with 350 g 150 Hz 150 Hz 125 Hz 125 Hz 93 Hz 93 Hz 640 Hz ±20 %
Resonant frequency in Y, unloaded 190 Hz 190 Hz 160 Hz 160 Hz 140 Hz 140 Hz 920 Hz ±20 %
Resonant frequency in Y, under load with 350 g 150 Hz 150 Hz 125 Hz 125 Hz 93 Hz 93 Hz 640 Hz ±20 %
Resonant frequency in Z, unloaded 380 Hz 380 Hz 315 Hz 315 Hz 250 Hz 250 Hz 1050 Hz ±20 %
Resonant frequency in Z, under load with 350 g 260 Hz 260 Hz 211 Hz 211 Hz 148 Hz 148 Hz 695 Hz ±20 %
Permissible push force in X 60 N 60 N 50 N 50 N 40 N 40 N 200 N max.
Permissible push force in Y 60 N 60 N 50 N 50 N 40 N 40 N 200 N max.
Permissible push force in Z 100 N 100 N 60 N 60 N 30 N 30 N 250 N max.
Permissible pull force in X 40 N 40 N 40 N 40 N 30 N 30 N 70 N max.
Permissible pull force in Y 40 N 40 N 40 N 40 N 30 N 30 N 70 N max.
Permissible pull force in Z 100 N 100 N 60 N 60 N 30 N 30 N 60 N max.
Overall mass 1450 g 1450 g 1450 g 1450 g 1450 g 1450 g 1550 g ±5 %
Material

Aluminum

Aluminum

Aluminum

Aluminum

Aluminum

Aluminum

Aluminum

 
Resonant frequency in X, under load with 100 g     145 Hz 145 Hz 120 Hz 120 Hz 860 Hz ±20 %
Resonant frequency in Y, under load with 100 g     145 Hz 145 Hz 120 Hz 120 Hz 860 Hz ±20 %
Resonant frequency in Z, under load with 100 g     275 Hz 275 Hz 215 Hz 215 Hz 950 Hz ±20 %
Miscellaneous P-561.3CD P-561.3CL P-562.3CD P-562.3CL P-563.3CD P-563.3CL P-561.3DD Tolerance
Operating temperature range -20 to 80 °C -20 to 80 °C -20 to 80 °C -20 to 80 °C -20 to 80 °C -20 to 80 °C -20 to 80 °C  
Connector D-sub 25W3 (m) LEMO LVPZT D-sub 25W3 (m) LEMO LVPZT D-sub 25W3 (m) LEMO LVPZT D-sub 25W3 (m)  
Cable length 1.5 m 1.5 m 1.5 m 1.5 m 1.5 m 1.5 m 1.5 m +50 / -0 mm
Recommended controllers / drivers

E-503, E-505, E-621, E-712, E-727

E-503, E-505, E-621, E-712, E-727

E-503, E-505, E-621, E-712, E-727

E-503, E-505, E-621, E-712, E-727

E-503, E-505, E-621, E-712, E-727

E-503, E-505, E-621, E-712, E-727

E-503, E-505, E-621, E-712, E-727

 
3D Models
3D Models
P-56x 3-D model
Version / Date

zip - 3 MB
Datasheet
Datasheet
Datasheet P-561 • P-562 • P-563
Version / Date
2023-04-26
pdf - 776 KB
Documentation
Documentation
Short Instructions PZ240
Piezo Positioning Systems: P-5xx / P-6xx / P-7xx
Version / Date
6.1.0 10/2019
pdf - 1 MB
Documentation
Technical Note P500T0002
Unpacking and Packing P-5xx Positioners
Version / Date
2019-03-04
pdf - 448 KB
Documentation
User Manual PZ248
P-561, P-562, P-563 PIMars XYZ Nanopositioning Systems
Version / Date
2.0.0 2022-11-24
pdf - 2 MB
Product Note
Product Note
Product Change Notification Piezo Actuator Driven Products
Version / Date
2021-04-19
pdf - 377 KB
P-561.3CD
PIMars nanopositioning stage; 100 µm × 100 µm × 100 µm travel range (X × Y × Z), capacitive, indirect position measuring; D-sub 25W3 (m)
P-561.3CL
PIMars nanopositioning stage; 100 µm × 100 µm × 100 µm travel range (X × Y × Z), capacitive, indirect position measuring; LEMO LVPZT
P-562.3CD
PIMars nanopositioning stage; 200 µm × 200 µm × 200 µm travel range (X × Y × Z), capacitive, indirect position measuring; D-sub 25W3 (m)
P-562.3CL
PIMars nanopositioning stage; 200 µm × 200 µm × 200 µm travel range (X × Y × Z), capacitive, indirect position measuring; LEMO LVPZT
P-563.3CD
PIMars nanopositioning stage; 300 µm × 300 µm × 300 µm travel range (X × Y × Z), capacitive, indirect position measuring; D-sub 25W3 (m)
P-563.3CL
PIMars nanopositioning stage; 300 µm × 300 µm × 300 µm travel range (X × Y × Z), capacitive, indirect position measuring; LEMO LVPZT
P-561.3DD
PIMars nanopositioning stage; 45 µm × 45 µm × 15 µm travel range (X × Y × Z); capacitive, indirect position measuring; D-sub 25W3 (m); direct drive
Direct the future with the power of the past.
Expertise
Markets Technologies
Contact
Nano Dünya Mak. San. Tic. Ltd. Şti.
Parseller Mah. Gündoğan Sok. No:8/A
Ümraniye/İstanbul

02166140039
info@nanodunya.com.tr
Copyright © 2024 by Nano Dünya. All rights reserved.
x
Quote List
Your quote list is currently empty.
x
Download Request
Your download list is currently empty.
0 0 Whatsapp